Electrical Rubber Mats

Vardhman Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other.

Electrical Rubber Matting manufactured by Vardhman conforms to IEC 61111 and comes with a double triangle logo. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

We at Vardhman, adopt the most advance technology to manufacture Insulating Mats. The state of the art line (German Technology) makes our quality and finish unmatchable in the industry.

All the testing and inspection facilities are established within the factory Which ensures every square inches of mat are fully tested to the specifications.

Application

The Mat can be used in Indoor and outdoor locations and are mostly used in front and rear side side of electrical panels, switchgears, transformers and other high voltage workplaces to provide the high safety environment for the workforce.

This mat can also be used as portable protection for site engineers working on live equipment.

Features and Advantages

  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
Class Standard Thickness Max. Use Voltage Proof Voltage Withstand Voltage Color Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

Note: Other thickness are also available on request. Maximum thickness offered in any class is 14mm.

Dimensions

Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties

S.No. Technical Specification All Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

Confirm Marking

The marking on the top side (always visible) of the safety mat will consist of following details:
The complete marking shall be marked at least once on every meter of mat. The marking shall be colour coded as per IEC 61111:2009 guidelines.
Class '0' - RED, Class '1' - WHITE, Class '2' - YELLOW, Class '3' - GREEN, Class '4' - ORANGE

Use and Storage Guide

Recommendation for use of IEC 61111:2009 standard live working-Electrical Insulating Mat.

The details are provided with regard to instructions for maintenance, inspections, retest and use of electrical insulating mats after purchase.

In cases where these recommendations are not followed, mats are not suitable for live working.

Storage/Transportation
Proper transportation and storage is must to protect the insulating properties and durability of mats. These mats shall not be bent or compressed. The mats should not be stored/used in the proximity of excessive heat sources. For maximum life of the mats do not store in open Sunlight, artificial light or any other sources of ozone for long hours.

Marking
Every Roll/Mat of the electrical Insulating mats shall have complete and visible marking as per IEC 61111:2009.

Before Use
Inspect visually each side of electrical insulating mats before use. If mat is dirty, wash it with respect of the operating temperature range.
Before use, the mats shall be inspected and if any cracks, tears or small pin holes are found then the mats shall be thought unsafe and returned for testing.

In Use
Ideal Operating Temperatures are -40 deg. cl. to 55 deg. cl. and avoid contact of mats with chemicals, solvents and strong acids as this adversely affect the life and properties of mats. Mats shall be placed on clean and smooth floor. Place the feet in the center of the mat.

Periodic Inspection and Testing
No electrical insulating matting, even those held in storage be used unless they have been inspected and/or electrically tested within the previous 12 months.
The tests on electrical insulating matting consist of visual inspection, and then a proof dielectric test without moisture conditioning, expect for class 0 where visual inspection only is required.

Class of Insulating Matting Type Test
Voltage KV Duration (Minute)
0 Visually Inspected
1 10 1
2 20
3 30
4 40

Note: Test requirements according to IEC 61111.

FAQ's

How do the insulating rubber matting works?

Specifically designed for use in front of high-voltage equipment such as switchboards, electrical safety matting is a special grade of rubber in mat form that has excellent insulating properties. Providing safety for operators and maintenance staff from electrical shock, it should be used in any area where the health and safety risk assessment has shown possible exposure to high-voltage shock.

Specially engineered matting for use in areas prone to electrical shock such as Switch boards. Vardhman IEC 61111 electrical safety matting is a special of rubber posses high insulation properties. These mats should be used in area where the risk assessment team has shown possible exposure to high voltage shock.

Rubber has inherent di-electric properties which inhibit the flow of electric charge as a result of its molecular structure and thus preventing the free flow of electrons. This makes it an ideal insulator.

How do i use an Electrical Safety Mat

In combination with personal protection equipment (such as electrically insulated gloves) the operator or user should stand on the mat in front of the electrical equipment. This will avoid a direct short through their body to the ground.

Guidelines for selection of class of electrical Insulating matting in relation to nominal voltage

The maximum use voltage recommended for each class of electrical insulating matting is designated in Table.

The maximum use voltage is the voltage rating of the protective equipment that designates the maximum nominal voltage of the energized system may be safely worked.

On multiphase circuits, the nominal voltage is equal to the phase-to-phase voltage. If there is no multiphase exposure is a system area, and the voltage exposure is limited to the phase to earth potential, the phase to earth potential should be considered to be the nominal voltage.

Class A.C. (V) (r.m.s.) D.C. (V)
0 1000 1500
1 7500 11250
0 17000 25500
0 26500 39750
0 36000 54000

If electrical equipment and devices are insulated, or isolated, or both, such that the multiphase exposure on an earthed neutral star circuit (grounded wye) is removed, the nominal voltage may be considered as the phase-to-earth voltage on that circuit.

The user may decide to use a different class of electrical insulating matting than that recommended in Table.